FEEDBACK
PLEASE WAIT ...
CLOSE
CLOSE

Manufacturer

Country

Registration Date 11 Jan 2018
Revision Date 11 Jan 2018
Share

ALSECURE NX 600

(0)

Renewable Energies Power Transmission

Cable

Nanomaterials

NPD Conjectured

Clay

Al2O3 • 2SiO2 • 2H2O Nanoparticle /Nanopowder CAS Number : 1332-58-7
Diameter : 2 nm

Properties

Fire resistance: BS 8491 120min. Flame propagation: BS EN 60266-2-4, IEC 60332-3-24. Smoke emission: BS EN 61034. Design: BS 7846. Certification: Certified by BASEC and LPCB.

Fire resistant Halogen-free

Manufacturer's Description

Alsecure NX600 is a Low Smoke Halogen Free fire resistant cable that is designed to meet the requirements in BS7846-F120 to maintain circuit integrity in the event of a fire. Alsecure NX600 is designed for use with fire safety engineering systems and is approved for 30,60 and 120 minute applications as described in BS8519. The cable is a halogen free, mica and XLPE insulated, LSF bedded, steel wire armoured and LSF sheathed cable with annealed copper conductors. For sizes up to and including 35mm² the conductors are circular, 50mm²-300mm² have sector shaped conductors. The armour is a single layer of galvanized steel wires. The cores are identified by colours and are laid up in a right hand direction and covered with an extruded layer of polymeric compound. The external surface on the outer sheath is embossed "NEXANS GS BASEC ELECTRIC CABLE BS 7846 F120 600/1000V LPCB 1242a/01 ALSECURE NX 600 NUMBER OF CORES X NOMINAL AREA OF THE CONDUCTOR YEAR OF MANUFACTURE" + metre marking. Alsecure NX 600 is as easy to install as standard SWA cables and no special tools is required.